The outdoor unit of the heat pump is covered in frost; occasionally the fan stops, and then white vapour rises from the unit. On the first few colder days, many owners are alarmed by these phenomena, even though in most cases this is simply the heat pump operating normally in winter. Icing and automatic defrosting do not indicate a fault.

But how can we tell if everything is working properly? What settings should we use to heat our homes efficiently, and when should we call in a professional? We’ll show you what to look out for when operating your heat pump in winter.

Why does the outdoor unit of a heat pump freeze over in winter?

An air-to-water heat pump extracts heat from the outside air and transfers it to the heating system. In heating mode, the surface of the outdoor heat exchanger is colder than the surrounding air, so moisture in the air may condense and then freeze on it.

Icing of the heat pump is common in humid weather around freezing point. In such conditions, more moisture can accumulate on the heat exchanger than on dry, bitterly cold days.

A thin layer of frost is therefore a natural phenomenon. However, if a thick layer of ice builds up on the outdoor unit and does not disappear even after defrosting cycles, this may indicate an operational problem.

How does the heat pump’s defrosting function work?

Modern air-to-water heat pumps detect when defrosting is required due to icing on the outdoor heat exchanger. At such times, most units temporarily reverse the refrigeration cycle and circulate warm refrigerant through the outdoor heat exchanger. The ice melts from the warming surface, and the resulting water is drained from the unit.

How often does the heat pump defrost?

There is no standard frequency for heat pump defrosting that applies to all units; the number of cycles is determined by the outside temperature, humidity, the unit’s load and the operation of the control system. A defrost cycle usually lasts a few minutes. During this time, the fan may stop and white vapour may rise from the outdoor unit. This is not smoke, but a natural phenomenon associated with defrosting.

However, if the appliance defrosts unusually often, is unable to remove the ice, or if its heating performance is consistently deteriorating as a result, it is worth having it checked.

Hőszivattyú részei és működése

Heat pump winter mode: how can we set it up to be energy-efficient?

One of the most important factors in winter operation is the flow water temperature. Generally speaking, the lower the temperature of the water used to heat the building, the more efficiently the heat pump operates.

Flow water temperature and heating curve

In the case of underfloor heating, a flow temperature of around 30–35 °C is sufficient in many buildings, whilst radiator systems may require a higher temperature. The optimum setting is determined by the building’s heat loss and the sizing of the heat emitters.

The weather-compensated control automatically adjusts the flow water temperature to the outdoor temperature. According to Daikin’s technical manual, a correctly set heating curve helps to reduce energy consumption and maintain a consistent indoor temperature.

Is it worth turning the heating down at night?

Heat pumps operate most efficiently when running at a steady rate. A significant drop in temperature overnight can be particularly detrimental in the case of underfloor heating with high thermal inertia, as a higher flow temperature may be required for reheating in the morning. A smaller reduction in temperature may result in savings in certain buildings.

It is important to note that the heat pump’s defrosting and frost protection functions are safety features which must not be switched off in order to reduce energy consumption.

How can we prevent problems caused by icy conditions in winter?

Unobstructed airflow is required for the outdoor unit to operate correctly. Accumulated snow, leaves and other obstructions must therefore be removed from the area around the unit.

It is just as important to ensure that the water produced during defrosting is properly drained away. If the water refreezes beneath the outdoor unit or in the drain pipe, a significant amount of ice may build up over time. To prevent this, proper drainage may be required, and in some installations, additional heating may also be necessary.

Ice that has formed on the outdoor heat exchanger must not be knocked off with a sharp object or melted with hot water, as this may damage the unit.

Hőszivattyú vagy klíma fűtésre? Részletes összehasonlítás és döntési útmutató

When does the heat pump’s winter operation indicate a fault?

If you experience the following symptoms, it may be advisable to seek professional advice:

Phenomenon Possible cause
The outdoor unit is covered in a thick layer of ice Defrosting or drainage problem
The equipment often shuts down with an error code Sensor fault, flow problem or other fault
The flat isn’t heating up properly Incorrect settings, insufficient performance or a system fault
The pressure in the heating system remains low A leak, a problem with the expansion tank or another cause of pressure loss
Unusual, loud noises are being heard Fan problem, obstruction caused by ice or mechanical fault

The noise emitted by the outdoor unit may change in cold weather due to the increased load and defrost cycles. For more details on normal operating noises and potential problems, see the Heat pump noise - how annoying and what can be done about it? You can read about this in our article entitled [...].

Why is it important to service a heat pump before the winter season?

Regular maintenance helps to identify, in good time, any problems that could lead to a drop in performance or a breakdown during the heating season.

SMARTAIR’s experts maintenance of the heat pump During this process, the following checks and tasks are carried out:

  1. Checking error logs: We will check whether the equipment recorded any faults or warnings during the previous period.
  2. Cleaning filters and sludge separators: Once the equipment has been shut down, we remove any debris that may be obstructing the proper flow of water.
  3. Checking expansion tanks: Once the system has been properly depressurised, check and adjust the pre-load pressure.
  4. Adjusting the water pressure: If necessary, we will pressurise the system to the specified pressure.
  5. Test run: We monitor the system parameters whilst it is in operation.
  6. Checking a three-way valve: We will check that the valve is working properly.
  7. Cooling circuit leak test: We carry out the required inspections on equipment that is subject to inspection under the relevant legislation.
  8. Cleaning an outdoor heat exchanger: We remove any dirt that impedes heat transfer and airflow.

The obligation to carry out leak checks is governed by Article 5 of EU Regulation 2024/573. The inspection requirement depends, amongst other things, on the type and quantity of refrigerant and the design of the equipment. Government Decree No. 458/2024 (30 December) sets out the domestic requirements for qualifications and the conduct of activities.

For further information on the benefits of regular checks, see the Heat pump maintenance - 5 reasons why you should also pay attention to this We covered this in detail in our article entitled ….

Frequently asked questions about heat pump operation in winter

Is it normal for a heat pump to freeze at minus 5 °C?
Yes. Icing can occur even below freezing point. A properly functioning system will automatically carry out the necessary de-icing.

Can the heat pump’s automatic defrost function be switched off?
Defrosting is a function essential to the operation of the appliance; therefore, switching it off or tampering with it is not recommended.

What happens to the heat pump in the event of a power cut in winter?
Without a power supply, the active frost protection functions and the circulation system may also stop working. This can pose a particular risk for monoblock heat pumps with an outdoor water circuit. For information on suitable frost protection solutions, see the Glycol or water - can a monobloc heat pump freeze? You can read about this in our article entitled [...].

Summary: correct settings and maintenance

De-icing the heat pump is part of normal winter operation; however, persistent icing or frequent malfunctions require inspection. A correctly set heating curve, the appropriate flow temperature and regular maintenance all contribute to economical and reliable operation.